Want to create an interactive transcript for this episode?
Podcast: HVAC School - For Techs, By Techs
Episode: Multiple Surge Protectors - Short #236
Description: In this short podcast episode, Bryan answers a listener-submitted question asking whether you can use another surge protector at the disconnect panel with an ICM 493 already in place. Using multiple surge protectors in the configuration described does NOT count as daisy-chaining. Surge protectors with MOVs (metal oxide varistors) shunt current from high voltage to ground by reducing their resistance. MOVs are sacrificial, so they wear out over time. Surge protectors don't last forever, so installing multiple is a fine idea. You can have whole-home surge protection with additional surge protectors positioned at the appliances/electronics...